Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 151954.015 - Employee is killed when crushed by de-barker machine

Accident Summary Nr: 151954.015 -- Report ID: 0418400 -- Event Date: 12/07/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1637984.01512/08/2022321920Battle Lumber Co., Inc.

Abstract: At 6:30 a.m. on December 7, 2022, an employee was removing wood bark from a de-barker machine at change of night shift when a day shift coworker started the de-barker. The employee was crushed and killed due to internal injuries.

Keywords: Actuated, Caught In, Cleaning, Crushed, Internal Injuries, Lockout, Lockout/Tagout, Logger, Logging, Removing, Stripping Machine, Wood Shavings

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1637984.015 31 M Fatality Miscellaneous woodworking machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.