Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 151935.015 - One employee is killed and another is injured in crane colla

Accident Summary Nr: 151935.015 -- Report ID: 0524530 -- Event Date: 12/06/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1637847.01512/06/2022532412Sterett Crane And Rigging Llc

Abstract: At 10:45 a.m. on December 6, 2022, employee #1, the lift director, and coworkers were installing a new kerosene hydrotreater reactor on its foundation at an oil refinery. The employees were lifting the reactor with a Terex 2800 Lattice Boom Track Crane when it tipped over and fell into a process flare line. Shackles had been installed the previous day to connect the super-lift counterweight frame to the connecting rods. Specific connecting rods were required by the manufacturer. During the lift, the two counterweight frame connectors sheared. The super-lift support rods became immediately free from the super-lift counterweight frame and fell with one section striking the head of employee #1. The crane dropped the load in the pipe rack. The superstructure counterweights fell from their racks and struck the crane cab knocking it under the boom. Employee #1 was killed due to head trauma. Employee #2, the crane operator, was hospitalized to treat head, back, hip, pelvis, and lower leg injuries as he fell from and exited the cab.

Keywords: Back, Blunt force, Blunt force trauma, Counterweight, Crane, Crane Cab, Crane Counterweight, Crane Load, Fall, Fall From Elevation, Falling Object, Fracture, Frame, Head, Hip, Leg, Lifting, Pelvis, Reactor, Refinery, Sheared, Struck By, Support Posts
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery New project or new addition   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1637847.015 47 M Fatality Crane Operator Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing equipment (HVAC and other)
Fatality Cause:
2 1637847.015 37 M Hospitalized injury Crane Operator Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing equipment (HVAC and other)
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.