Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 151727.015 - Employee is killed when struck and crushed by excavator

Accident Summary Nr: 151727.015 -- Report ID: 0521100 -- Event Date: 11/30/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1636507.01512/01/2022237110Superior Sewer And Water Inc.

Abstract: At 1:58 p.m. on November 30, 2022, an employee was working with three coworkers preparing a site for a drainage pipe installation. The crew foreman was operating a John Deere 350P excavator, weighing over 89,000 pounds. The employee was operating a haul truck to remove excess soil from the area and was rigging the 15-inch advanced drainage system pipe sections for the excavator to move into place. Another coworker was the crew pipe layer, making the pipe section connections and preparing the pipe installation for ground cover. The third coworker was operating a bulldozer. The employee and the pipe layer moved a section of pipe closer to the excavator. The employee then approached the excavator to communicate with the foreman. The foreman saw the employee approaching and set down the excavator bucket. The excavator was not turned off nor was the pilot shutoff lever pulled. Due to the weather and wind conditions, the excavator window and door were closed at the time. The employee was standing in front of the left track and attempted to verbally communicate with the foreman. The foreman opened the cab door and the wind slammed the door against the side of the machine. The excavator lurched forward twice, initially knocking the employee to the ground, then running him over up to the waist. The foreman pulled the safety lever to disengage the machine. The pipe layer yelled for the foreman to back up in order to free the employee. The foreman disengaged the lever and used the bucket to raise the tracks up. The pipe layer pulled the employee out from under the track. The coworkers covered the employee with jackets until emergency personnel arrived at the site. The employee was taken to the hospital but died due to his injuries.

Keywords: Bulldozer, Crushed, Crushing, Drain Pipe, Excavator, Installing, Loader Bucket, Run Over, Struck By
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition   0 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1636507.015 37 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close