Accident Summary Nr: 150905.015 - Employee burns and crushes hand when caught in hot stamp mac

Accident Summary Nr: 150905.015 -- Report ID: 0950635 -- Event Date: 06/29/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1605744.01506/29/2022333511Arthurmade Plastics, Inc

Abstract: At 1:30 p.m. on June 29, 2021, an employee was working as an electrician/maintenance technician for plastic container manufacturer. Raw resin is injected or blow molded after which time the containers are run through an automated system that performs finishing operations including hot stamping labels. The employee was adjusting the hot stamp plate on a MAS Automated Pail System machine #9 (Serial #11187). Coworker #1, the automation/maintenance manager, is the employee's supervisor. The employee reported being instructed to change the machine from 4.5 gallon buckets to 5.5 gallon buckets. The employee needed to adjust the labeling part of the hot stamp. While the machine was operating he opened the interlocked front door. The employee needed to adjust the laser for the bucket label which required adjusting the bucket. He reached into the machine and was manually turning the bucket when the hot stamp activated and caught his hand. The employee said lockout tagout was not required on this particular machine. Coworker #2, the production floor lead, reported that the hot stamp only works when activated by a bucket and the employee asked for help putting the buckets in the machine to observe it running. Coworker #2 said that he saw the employee put a piece of metal in or over the sensor so he could work with the door open and the machine running. The employee was manually turning the bucket to adjust the labeling part when the machine activated and the laser stamped a label on the bucket. Coworker #1 said they looked for a piece of metal to defeat the interlock sensor but could not find it. The employee denied attempting to defeat the interlock. The employee sustained crush injuries and third degree burns to his left hand. The employee was taken to the hospital, where his wound was cleaned and he was sent home. On July 1, 2021, the employee went back to the hospital, where he was admitted and spent approximately 15 days in the hospital to treat his injury.

Keywords: Adjust, Burn, Bypass, Bypass Guard, Caught Between, Caught In, Crushed, Die Safety Device, Electrician, Fracture, Hand, Heat, Hot Plastic, Interlock, Lack of Work Procedures, Lockout, Lockout/Tagout, Machine Cycled, Machine Guarding, Machine operator, Maintenance, Manufacturing, Mechanic, Misjudgment, Misjudgment of Hazardous Situation, Production Line, Reaching In, Safety Device, Stuck, Technician

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1605744.015 69 M Hospitalized injury Not specified mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.