Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 150730.015 - Employee Is Killed When Crushed By Falling Quartz Slab

Accident Summary Nr: 150730.015 -- Report ID: 0854910 -- Event Date: 10/22/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1629980.01510/24/2022327991Creative Granite & Design, Llc

Abstract: At 12:15 a.m. on October 22, 2022, an employee was attempting to move a slab of quartz from a 26 foot truck bed at a cut stone manufacturing facility. The truck bed contained two 500 lb slabs of quartz. A gust of wind caught the quartz slab which struck and knocked over the employee before landing on top of him. The employee was killed by crushing injuries.

Keywords: Crushed, Crushing, Falling Object, Rock, Struck By, Unloading, Unsecured, Windy
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Other   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1629980.015 54 M Fatality Misc. metal,plastic,stone&glass-working mach. op's Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.