Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 150216.015 - Employee is killed in fall while installing roofing

Accident Summary Nr: 150216.015 -- Report ID: 0551800 -- Event Date: 10/04/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1626391.01510/05/2022236115Swiss Builders Llc

Abstract: At 12:15 a.m. on October 4, 2022, an employee (Foreman) was working for a company constructing a travel trailer factory. The employee was working on a crew of 5 coworkers installing insulation and metal roofing on the building. The crew went down from the roof to have lunch. After lunch, they returned to the roof to continue the installation. The employee came up on the roof and was observed not wearing his harness. He then went to the north side of the building where he was working prior to lunch. He did not put on any fall protection equipment, then he bent over to stretch out the insulation prior installing the metal panel. He apparently overstepped and placed his foot onto the insulation as he was bending over. He then appeared to step to close or over the edge, lost his balance and fell forward onto the concrete floor 25 feet below. The employee died from blunt force trauma to the head when he hit face first onto the concrete floor.

Keywords: Blunt force, Blunt force trauma, Concrete Floor, Construction, Fall, Fall From Elevation, Fall Protection, Fracture, Harness, Head, Installing, Insulation, Lost Balance, Misjudgment, Misjudgment of Hazardous Situation, Protective Clothing, Roofer, Work Surface
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition   1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1626391.015 25 M Fatality Distance of Fall: 32 feet
Worker Height Above Ground/Floor: 32 feet
Cause: Roofing
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.