Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 149258.015 - Employee Is Killed When Crushed In Lumber Machine After Clea

Accident Summary Nr: 149258.015 -- Report ID: 0627100 -- Event Date: 08/26/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1618264.01508/27/2022321912Anthony Timberlands, Inc.

Abstract: At 9:15 p.m. on August 26, 2022, an employee was operating a Sharp Chain, Model 3916-001 machine at a lumber resawing and planing facility. When the machine indicated by error message that there was a blockage at the photo eye lens sensor/profiler head, the employee entered the machine and attempted to remove the blockage. When the employee cleared the blockage, the machine activated and the employee was pinned and crushed between the profiler and the machine frame. The employee was killed when he suffered lacerations from the machine blades and blunt force to the chest, neck and back of the head.

Keywords: Automatic Restart, Blade, Blunt force, Blunt force trauma, Caught Between, Chest, Clogged, Crushed, Crushing, Head, Laceration, Lumber, Machine Cycled, Machine operator, Neck, Pinned, Wood

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1618264.015 44 M Fatality Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close