Accident Summary Nr: 149183.015 - Employee dies from electrical shock and fall during roofing

Accident Summary Nr: 149183.015 -- Report ID: 0552651 -- Event Date: 08/23/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1617633.01508/24/2022238160American Metal Roofs Inc.

Abstract: At 2:45 a.m. on August 23, 2022, an employee was working as a roofer for a roofing contractor installing a metal roof on a residential home. The employee climbed a secured ladder while carrying a 10-foot piece of metal trim. A coworker called out to the worker on the ladder causing him to turn around. At this point, the metal trim contacted a live electrical line causing him to fall approximately 18 feet to the ground. EMS transported the employee to the hospital, where he died.

Keywords: Blunt force, Blunt force trauma, Clearance, Climbing, Construction, Contact, Electric Shock, Electrical Wire, Fall, Fall From Elevation, Installing, Ladder, Metal, Residential Construction, Roof, Roofer, Shock
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition   X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1617633.015 46 M Fatality Distance of Fall: 30 feet
Worker Height Above Ground/Floor: feet
Cause: Roofing
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.