Accident Summary Nr: 149018.015 - Two employees are killed in hazardous atmosphere

Accident Summary Nr: 149018.015 -- Report ID: 0524530 -- Event Date: 08/19/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1616318.01508/20/2022238190Pfund Construction Company, Inc.

Abstract: At 6:15 p.m. on August 19, 2022, two employees were digging a trench with a JCB 245XR Excavator for a storm sewer line that was located in the center of a new multi-residential housing complex that was under construction. The trench was approximately 29 feet long by 16 feet wide and 7 feet 6 inches deep. Both employees entered into a manhole section of an existing sanitation sewer line that was located approximately 6 feet from the trench. Both employees lost consciousness in the manhole section. The EHS service that attempted to conduct the rescue of the employees noted that the oxygen levels were at 12.1%. The employer had completed this sanitation sewer line prior to working on the storm sewer line. The employer did not have a means of testing the atmosphere in the manhole section, and the employees were not trained on OSHA requirements for working around and entry into confined spaces. Both employees died of asphyxiation.

Keywords: Asphyxiated, Atmosphere, Confined Space, Excavation, Excavator, Lack of oxygen, Lost consciousness, Manhole, Oxygen, Oxygen Deficiency, Toxic Atmosphere, Trench, Trench Digger
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant New project or new addition   0 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1616318.015 22 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing underground plumbing conduit
Fatality Cause:
2 1616318.015 19 M Fatality Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing underground plumbing conduit
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.