Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 147672.015 - Employee falls through skylight, receives fractures to right

Accident Summary Nr: 147672.015 -- Report ID: 0950643 -- Event Date: 01/10/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1579550.01502/07/2022238220Acosta Heat And Air Conditioning, Inc.

Abstract: At 11:30 a.m. on January 10, 2022, an employee delivered materials onto a roof. As the employee walked by to the roof egress point, the employee tripped and fell approximately twelve feet through an unguarded skylight. The employee was hospitalized to treat fractures to the right elbow, neck, and back.

Keywords: Access/Egress, Back, Elbow, Fall, Fall From Elevation, Fall Protection, Fracture, Neck, Roof, Skylight, Tripped, Unguarded
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Maintenance or repair   3

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1579550.015 25 M Hospitalized injury Installers And Repairers Distance of Fall: 12 feet
Worker Height Above Ground/Floor: 12 feet
Cause: Installing equipment (HVAC and other)
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.