Accident Summary Nr: 147123.015 - Employee is killed after being asphyxiated in excavation

Accident Summary Nr: 147123.015 -- Report ID: 0830500 -- Event Date: 06/18/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1603037.01506/18/2022238910Roland Transportation Services

Abstract: At 3:25 p.m. on June 18, 2022, an employee was in an excavation in the process of repairing a 4-inch PVC sewer line. The sewer line was located at a the end of a shared residential driveway. After a coworker started up a mini-excavator, he noticed the interior trench wall of the excavation started sloughing. The employer told the employee to stay in the pothole area of the excavation. As the employee attempted to move in the direction towards the pothole area the wall collapsed. The employee was trapped, crushed and asphyxiated and died.

Keywords: Asphyxiated, Caught In, Collapse, Competent Person, Construction, Crushed, Excavation, Excavator, Lack of Engineering Controls, Misjudgment, Misjudgment of Hazardous Situation, Multi-employer Worksite, Multiemployer, Pipe, Plumbing, Residential Construction, Sewer, Struck By, Trapped, Trench, Unstable Position, Unstable Soil, Unstable Surface
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Maintenance or repair   13 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1603037.015 33 M Fatality Construction Laborer Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close