1571948.01501/11/2022311412Leprino Foods Company

Abstract: At 8:00 a.m. on December 22, 2021, an employee, a maintenance technician, was repairing a 700-series Tri-Clover air-actuated in-line valve that was secured in a pipe vise, when the valve fell. As the valve was falling, the air-line supplying air to it became disconnected causing the valve to close. The employee reached to try and catch the valve. When he grabbed it, his hand made contact with the pinch point of the closing valve. The employee's thumb was crushed in the valve and he was hospitalized to treat a thumb amputation.

Keywords: Air Line, Amputated, Amputation, Crushed, Disconnecting Means, Falling Object, Maintenance, Nip Point, Pinched, Reaching, Repair, Thumb, Valve

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1571948.015 57 M Hospitalized injury Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close