Accident Report Detail
Accident Summary Nr: 146425.015 - Employee Is Killed When Run Over By Scraper
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
1597717.015 | 05/20/2022 | 237110 | Strack Incorporated |
Abstract: At 7:30 p.m. on May 19, 2022, an employee was performing site grading and rock removal during construction at a residential site. While operating a Caterpillar, Model 621F scraper, the employee fell from the cab while moving in second gear because he was not wearing the seat belt available. The employee was killed when he was run over and crushed by the scraper.
End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
---|---|---|---|---|---|---|---|
Single family or duplex dwelling | New project or new addition | X |
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
---|---|---|---|---|---|---|---|
1 | 1597717.015 | 16 | M | Fatality | Equipment Operator: Heavy | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Site grading and rock removal Fatality Cause: |