Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14570691 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU TREE LIMB

Accident Summary Nr: 14570691 -- Report ID: 0524700 -- Event Date: 08/21/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10167414108/25/198607830Asplundh Tree Expert Company

Abstract: AN EMPLOYEE WAS TRIMMING A TREE. THE TREE BRANCH HE WAS TRIMMING CONTACTED A 138-KILOVOLT OVERHEAD POWER LINE, ELECTROCUTING THE EMPLOYEE.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, TREE LIMB, ELECTROCUTED, E GI IC, TREE TRIMMING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101674141 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close