Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14570055 - EMPLOYEE DROWNED IN MUD AT OIL WELL DRILLING SITE

Accident Summary Nr: 14570055 -- Report ID: 0522500 -- Event Date: 01/28/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10112375001/29/198613810Dyanmic Drilling Inc Rig 4

Abstract: ON JANUARY 28, 1986, EMPLOYEE #1 WAS EMPLOYED AT AN OIL WELL DRILLING SITE WHICH UTILIZED A ROTARY RIG. WATER WAS BEING FORCED UP AROUND THE OUTSIDE OF THE CONDUCTER PIPE OR CASING, BUT COULD NOT ESCAPE TO THE SURFACE BECAUSE OF FROZEN GROUND. A LARGE VOID, NOT DETECTABLE FROM THE SURFACE, WAS THEREFORE CREATED AROUND THE CASING. WHEN EMPLOYEE #1 WALKED ONTO THE SURFACE ABOVE THE VOID, THE GROUND COLLAPSED UNDER HIM. HE DROWNED IN THE ACCUMULATION OF MUD AND WATER IN THE VOID.

Keywords: COLLAPSE, OIL WELL DRILLING, DROWN, FROZEN, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101123750 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.