Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14566939 - EXPLOSION ON HIGH PRESSURE HYDRAULIC PRESS

Accident Summary Nr: 14566939 -- Report ID: 0454510 -- Event Date: 12/13/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1534236312/14/198430110Long Mile Rubber Company

Abstract: EMPLOYEE #1 WAS MAKING AN ADJUSTMENT ON A PRESSURE RELEASE SWITCH WHEN THE HIGH PRESSURE LINE EXPLODED. A PIECE OF THE METAL LINE STRUCK THE EMPLOYEE IN THE HEAD. THE ACCIDENT OCCURRED IN THE HYDRAULIC PIT BELOW THE RUBBER PRESS. THE EMPLOYEE WAS USING A SCREWDRIVER AND ADJUSTABLE WRENCH TO MAKE AN ADJUSTMENT WHILE THE PRESS WAS RUNNING. THE PRESSURE IN THE LINE WAS BETWEEN 3200 AND 3250 PSI WHEN THE LINE EXPLODED.

Keywords: HEAD, EXPLOSION, HIGH PRESSURE PIPE, STRUCK BY, FLYING OBJECT, HYDRAULIC PRESS, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15342363 Fatality Amputation Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.