Accident Summary Nr: 14566897 - RUNAWAY REACTION PRODUCED SULFUR DIOXIDE, EMPLOYEE EXPOSED

Accident Summary Nr: 14566897 -- Report ID: 0454510 -- Event Date: 07/29/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
320877408/30/198528690Abco Industries Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
320885709/05/198532730Chapman Grading & Concrete

Abstract: ON JULY 29, 1985, 4,200 POUNDS OF THIOUREA DIOXIDE AND 800 POUNDS OF SODIUM SULFATE WERE MIXED IN A 5,000 POUND CAPACITY STAINLESS STEEL BLENDER. A SELF-SUSTAINING OXIDATION REACTION OCCURRED, CONSUMING ALL THE MATERIAL IN THE BLENDER. LARGE AMOUNTS OF SULFUR DIOXIDE WERE RELEASED AS A DECOMPOSITION PRODUCT. THE GAS ESCAPED FROM THE VESSEL THROUGH A GASKET WHICH RUPTURED DUE TO THE PRESSURE BUILD-UP. ONE EMPLOYEE WHO WORKED IN AN ADJACENT RECEIVING AREA INHALED SULFER DIOXIDE WHILE LEAVING THE BUILDING. HE WAS TREATED FOR PULMONARY IRRITATION BY THE COMPANY PHYSICAN. HE WAS RELEASED THE SAME AFTERNOON AND RETURNED TO WORK THE NEXT MORNING. ALL THE OTHER EMPLOYEES WERE EVACUATED WITHOUT SIGNIFICANT EXPOSURE. THE CHEMICAL REACTION COULD HAVE BEEN INITIATED BY HEAT BUILD-UP ON A FAULTY COUPLING ON THE INTENSIFIER BAR, OR BY CONTAMINATION BY MOISTURE OF THE RAW MATERIALS, OR A COMBINATION OF THE TWO FACTORS.

Keywords: RESPIRATORY, INHALATION, SULFUR DIOXIDE, HEAT, CHEMICAL REACTION, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3208774 Non Hospitalized injury Other Freight, stock and material handlers, n.e.c.
2 3208857 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.