Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14565923 - CAUGHT IN CONVEYOR BELT

Accident Summary Nr: 14565923 -- Report ID: 0950411 -- Event Date: 06/28/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1462255906/30/198424210Evergreen Lumber Co Inc

Abstract: ON JUNE 28, 1984, SOMETIME BETWEEN THE HOURS OF 9:15 PM AND 10:10 PM, IT APPEARS THAT EMPLOYEE #1, A BOILER OPERATOR, CLIMBED UP TO THE MAINTENANCE PLATFORM AT THE EAST END OF THE CONVEYOR BELT SYSTEM. FOR SOME REASON HE APPARENTLY REACHED THROUGH A 12 BY 13 INCH OPENING INTO THE CONVEYOR BELT AREA. THE BELT GRABBED HIS HAND, PULLING HIM INTO THE CONVEYOR. HE WAS COMPLETELY DISMEMBERED.

Keywords: MAINTENANCE, CONVEYOR BELT, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14622559 Fatality Other Stationary engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.