Accident Summary Nr: 145659.015 - Employee is killed when crushed by demolished chimney

Accident Summary Nr: 145659.015 -- Report ID: 0950614 -- Event Date: 04/21/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1591388.01504/21/2022238110Ashish Goyal

Abstract: At 1:15 p.m. on April 21, 2022, a Contractor was hired by a homeowner of a single-story residential property to perform renovations and build an addition to the existing structure. This involved miscellaneous demolition work and construction of foundations and footings, and framing. The employee and a coworker, his son, were assigned to demolish the existing fireplace and indoor BBQ wall and chimney between the kitchen and the living room. These structures consisted of bricks and cement masonry units structurally supported by a wall. The chimney went through the roof. The employee and coworker were demolishing the wall and chimney from the bottom up inside of the kitchen with a rotary hammer. The upper portion of the chimney fell through the composite shingle roof and landed on top of the employee crushing his torso. The chimney was too heavy to lift off of the employee and the homeowner called 911. The Fire Department responded and found the employee unresponsive. The Contractor was not licensed which meant that the homeowner became the employer. The collapse could have been prevented by demolishing the chimney from the top down and structurally supporting it by shoring, bracing, or other effective means. The employee was killed due to the blunt impact and crushing force on his chest, neck, and lower limbs.

Keywords: Back, Blunt force, Blunt force trauma, Bracing, Brick, Chest, Chimney, Collapse, Construction, Crushed, Demolition, Falling Object, Inexperience, Lack of Engineering Controls, Lack of Work Procedures, Leg, Masonry, Masonry Wall, Misjudgment, Misjudgment of Hazardous Situation, Neck, Residential Construction, Shoring, Struck By, Structural Collapse
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Alteration or rehabilitation   1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1591388.015 56 M Fatality Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.