Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14565691 - Employee injured in fall when scaffold platform dislodged

Accident Summary Nr: 14565691 -- Report ID: 0950411 -- Event Date: 02/28/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
254653902/28/198617410Statewide Masonry Inc

Abstract: Employee #1 was working as a laborer on a Morgan-type scaffold that was set between two towers. He was working at a height of approximately 27 feet, transferring concrete block to a material platform, when the platform on which he was standing became displaced from the support brackets and dropped from under him. Employee #1 fell to the ground and suffered severe leg injuries. The main causal factor for this accident was the use of improper platforms that were not sufficiently long and were not secured to prevent movement.

Keywords: UNSECURED, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, FALL, ELEVATED WORK PLAT, WORK PLATFORM, LEG, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2546539 Hospitalized injury Dislocation Brickmasons and stonemasons apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.