Accident Summary Nr: 14554281 - GRAIN DUST EXPLOSION

Accident Summary Nr: 14554281 -- Report ID: 0728900 -- Event Date: 05/15/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
189111805/16/198551530Shickley Grain Co Inc

Abstract: ON MAY 15, 1985, AT APPROXIMATELY 4:15 PM, EMPLOYEES #1 AND #2 WERE PREPARING TO DUMP A LOAD OF CORN INTO THE DUMP PIT OF A GRAIN ELEVATOR. EMPLOYEE #2 WAS IN THE TRUCK RAISING THE BOX. EMPLOYEE #1 WAS CHANGING THE DISTRUBUTOR HEAD FROM BIN 5 TO BIN 8. AN EXPLOSION OCCURED. EMPLOYEE #1 WAS BLOWN OUT THE EAST DOOR OF THE DRIVE. HE RECEIVED SECOND AND THIRD DEGREE BURNS OVER 40 PERCENT OF HIS BODY. EMPLOYEE #2 WAS TAKEN TO THE HOSPITAL FOR A CHECK-UP AND RELEASED.

Keywords: BURN, DUST, CORN, EXPLOSION, TRUCK, COMBUSTIBLE DUST, GRAIN ELEVATOR, GRAIN DUST

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1891118 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 1891118 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.