Accident Summary Nr: 14553440 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL WIRE

Accident Summary Nr: 14553440 -- Report ID: 0729300 -- Event Date: 06/28/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
11388632906/29/199517410Heitkamp Masonry Inc

Abstract: Two bricklayers were building a block wall. One of the employees (employee #1) had been working with the company for about 1 month; the other employee had been working with the company for only 3 days. They were working from a Morgan tower scaffold about 5.5 meters above the ground. The base of the scaffold was about 1.2 meters horizontally from a 7200-volt overhead power line. As the wall was built, the scaffold was raised until the work platform was in line with the power line. In spite of this, neither the general contractor nor the masonry contractor (the employees' employer) contacted the electric utility owning the line about removing or controlling the hazard. One of the employees (employee #1) handed the other a piece of reinforcing wire (called ladder wire due to its shape), and the second employee laid the wire along the length of the wall. The first employee raised the outside edge of the reinforcing wire to allow the second employee to cut it to length with a pair of bolt cutters. As the second employee cut the wire, it flipped into the overhead power line, which was only about 1.2 meters from where the two employees were standing. The first employee was electrocuted. The second employee sustained an electric shock and was hospitalized for his injury.

Keywords: METAL WIRE, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E C, ELECTRIC SHOCK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 113886329 Fatality Electric Shock Brickmasons and stonemasons
2 113886329 Hospitalized injury Electric Shock Brickmasons and stonemasons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close