Accident Summary Nr: 14550578 - CRUSHED BETWEEN COUPLERS ON RAILROAD TANK CARS

Accident Summary Nr: 14550578 -- Report ID: 1032500 -- Event Date: 09/07/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
158601508/08/198428740Beker Industries Corporation

Abstract: ON AUGUST 7, 1984, AT APPROXIMATELY 6:30 PM, EMPLOYEE #1, A BRAKEMAN, WAS SWITCHING RAIL CARS FOR WEIGHING. WHILE THE ELEVEN CAR TRAIN, WITH ENGINE, WAS IN MOTION EMPLOYEE #1 STEPPED BETWEEN THE SECOND AND THIRD CARS, SEPARATED THE COUPLERS AND TURNED OFF THE AIR BRAKE COCK ON THE THIRD CAR. HE THEN TOLD THE ENGINER TO SPEED UP. AS THE ENGINE THROUGH SECOND CAR ACCELERATED, THE AIR HOSE CONNECTION BETWEEN THE SECOND AND THIRD CARS WAS PULLED APART. BRAKE AIR PRESSURE THEN ESCAPED FROM THE BRAKE SYSTEMS OF THE ENGINE AND CARS 1 AND 2, ACTIVATING THE EMERGENCY BRAKING SYSTEM. AS THE ENGINE AND FIRST TWO CARS SLOWED DOWN, THE BRAKEMAN SAW HIS MISTAKE AND STEPPED BETWEEN CARS 2 AND 3 AGAIN TO RECTIFY THE PROBLEM. CARS 3 THROUGH 11, NOW ROLLING FASTER THAN THE ENGINE AND CARS 1 AND 2, STRUCK EMPLOYEE #1 AND CRUSHED HIM AGAINST THE STOPPED ENGINE AND CARS 1 AND 2.

Keywords: BRAKE, RAILROAD TANK CAR, BRAKEMAN, CRUSHED, AIR HOSE, RAILROAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1586015 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close