Accident Summary Nr: 14549547 - ELECTRIC SHOCK - ACCIDENTALLY ENERGIZED WELDER FRAME

Accident Summary Nr: 14549547 -- Report ID: 0454714 -- Event Date: 05/26/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
1517933605/30/198417990Joe Hill Company Incorporated

Abstract: THREE EMPLOYEES WERE LIFTING AN ELECTRIC WELDER WITH A CHAIN HOIST ON A MONORAIL SYSTEM. THE EMPLOYEES INTENDED TO LIFT THE WELDER HIGH ENOUGH TO CLEAR A 5-FOOT-HIGH STAIRCASE SO THAT THEY COULD MOVE THE WELDER HORIZONTALLY. EMPLOYEE #1 HAD BEEN INSTRUCTED TO UNPLUG THE WELDER, WHICH HAD AN ATTACHED FLEXIBLE CABLE ABOUT 60 FEET LONG. WHEN HE RETURNED, ONE EMPLOYEE STARTED TO LIFT THE CHAIN HOIST, ANOTHER EMPLOYEE WAS PULLING HORIZONTALLY, AND EMPLOYEE #1 WAS PUSHING. THE LIFTING, PULLING, PUSHING FORCES ON THE WELDING MACHINE CAUSED THE STILL-CONNECTED 440-VOLT FLEXIBLE CABLE TO PULL OUT OF THE CABLE CONNECTOR AT THE MACHINE AND SHORT AGAINST THE FRAME OF THE MACHINE. EMPLOYEE #1 RECEIVED A SEVERE ELECTRIC SHOCK, CAUSING HIM TO JERK VIOLENTY, WHICH ALLEDGEDLY KNOCKED HIS HARD HAT OFF. HE THEN FELL BACKWARDS FROM A HEIGHT OF ABOUT 27 INCHES FROM THE FLOOR (HE WAS ON THE THIRD STEP OF THE STAIRCASE), FRACTURING HIS SKULL IN TWO PLACES. AFTER AN AUTOPSY WAS PERFORMED, THE CORONER STATED THAT CAUSE OF DEATH WAS ELECTROCUTION.

Keywords: ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED, WELDER, E C, CORD CONNECTOR, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 15179336 Fatality Electric Shock Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close