Accident Summary Nr: 14548556 - Employee injured when buried in trench cave-in

Accident Summary Nr: 14548556 -- Report ID: 0951510 -- Event Date: 04/12/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1467516904/15/198516230Haitsuka Brothers Ltd

Abstract: At approximately 1:45 p.m. on April 12, 1985, Employee #1 and a coworker were attempting to break up and remove a bed of rocks located at the bottom of an approximately 3 ft 5 in. wide by 17 ft deep by 38 ft long sewer line trench when the east wall caved in. Employee #1, who was running to the escape the falling bank, was buried under at least 5 ft of dirt for about five minutes. He sustained hypoxia, a brain injury, a fractured scapula and a possible injury to his right eye. The coworker was not injured. The trench walls were neither sloped nor shored.

Keywords: OXYGEN DEFICIENCY, FRACTURE, WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, BURIED, CAVE-IN, BRAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 14675169 Hospitalized injury Fracture Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close