Accident Summary Nr: 14547731 - Employee's ankles fractured in jump from scaffold

Accident Summary Nr: 14547731 -- Report ID: 1050210 -- Event Date: 10/31/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10366410810/31/198892240Kodiak City Fire Department

Abstract: At approximately 9:25 a.m. on October 31, 1988, Employee #1, an assistant fire chief, was climbing the end bracing of a 13 ft 10 in. high scaffold. The scaffold started to sway and shake, and Employee #1 jumped off because he thought it would overturn. He landed on a concrete floor and fractured both ankles. The scaffold overturned after he jumped, but it is possible that this was a result of his jumping. Safety instructions on the scaffold indicated that outriggers and/or tying off to the building are required if the platform height exceeds 8 ft 6 in. At the time of the accident, the platform height was 9 ft 10 in., and neither precaution had been taken.

Keywords: FRACTURE, OUTRIGGER, WORK RULES, FALL, TIE-OFF, ANKLE, OVERTURN, SCAFFOLD, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103664108 Hospitalized injury Fracture Supervisors, firefighting & fire prevention occupa

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close