Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14546410 - Employee dies of asphyxia in helicopter fuel cell

Accident Summary Nr: 14546410 -- Report ID: 0418600 -- Event Date: 05/13/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10122815305/16/198937210Mcdonnell Douglas Helicopter Co., Inc.

Abstract: Between 2:30 and 3:00 p.m. on May 12,1989, Employee #1 went to replace a valve in a helicopter's fuel cell. The fuel had been taken out of the cell on May 9, 1989. The employee climbed down into the fuel opening through a 10 inch by 16 inch opening in the top of the cell. Employee #1's body was found on May 13, 1989. It was determined that he had died of asphyxia.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, REPAIR, CONFINED SPACE, WORK RULES, HELICOPTER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101228153 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.