Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14543607 - CONSTRUCTION EMPLOYEE KILLED IN TRENCH CAVE-IN

Accident Summary Nr: 14543607 -- Report ID: 0317740 -- Event Date: 01/07/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10039905401/08/198717940Mast Excavating Inc.

Abstract: EMPLOYEE #1 WAS WORKING IN A TRENCH 9 FEET DEEP AND 30 FEET LONG, INSTALLING A SANITARY SEWER LATERAL HOOK UP. THE SIDE WALLS CONSISTED OF UNSTABLE SOIL. THE TRENCH WAS NOT SHORED, SLOPED, OR OTHERWISE SUPPORTED. A SECTION OF THE WEST WALL COLLAPSED ONTO THE EMPLOYEE, KILLING HIM.

Keywords: SEWER, WORK RULES, CONSTRUCTION, TRENCH, CRUSHED, SHORING, UNSTABLE SOIL, SLOPING, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100399054 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.