Accident Summary Nr: 14543243 - BURN - ELECTRICAL - FAULT IN OIL CIRCUIT BREAKER

Accident Summary Nr: 14543243 -- Report ID: 0317740 -- Event Date: 08/02/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
113612608/03/198433120Bethlehem Steel Corporation-Beth Forge Division

Abstract: SEVEN POWER GROUP DEPARTMENT EMPLOYEES WERE ASSIGNED TO PERFORM MAINTENANCE ON A 6.9-KILOVOLT, 25-CYCLE TRANSFORMER BANK. THE MAINTENANCE WAS TO INCLUDE INSPECTING THE EQUIPMENT, CHANGING THE CIRCUIT BREAKER OIL, AND CLEANING THE TRANSFORMER BUSHINGS. THE WORK WAS TO BE COORDINATED SO THAT THE BUILDING HOUSING THE OIL CIRCUIT BREAKER COULD BE REPAIRED BY CARPENTERS AT THE SAME TIME. BEFORE THE MAINTENANCE WAS STARTED, IT WAS NECESSARY TO ISOLATE THE EQUIPMENT FROM THE POWER SOURCE. EMPLOYEE #1 CLOSED THE 230-VOLT TIE DISCONNECTS AND OPENED 6 DELTA DISCONNECTS TO TAKE THE LOAD OFF THE SECONDARY POWER SIDE. HE PLACED RED TAGS ON EACH DELTA DISCONNECT. EMPLOYEE #1 THEN CHECKED CURRENT TO THE TRANSFORMERS WITH AN AMMETER. THE CHECK SHOWED NO LOAD. HE THEN ATTEMPTED TO OPEN THE 6.9-KILOVOLT OIL CIRCUIT BREAKER. AS HE OPENED THE BREAKER, A LARGE FLASH OCCURRED, AND THE BUILDING CAUGHT ON FIRE. (THE OIL CIRCUIT BREAKER WAS A GENERAL ELECTRIC FK BREAKER #S DKL 140569 59406, WSF 23308; RATED 300 AMPERES, 15 KILOVOLT, 3-PHASE; A SINGLE-TANK UNIT OF 1920 VINTAGE.) EMPLOYEES # 1, 2, AND 3 WERE INSIDE THE OIL CIRCUIT BREAKER BUILDING, AND EMPLOYEES #4, 5, 6, AND 7 WERE OUTSIDE THE BUILDING WHEN THE FLASH OCCURRED. SIX EMPLOYEES SUFFERED BURNS. ONE HAD LACERATIONS AND CONTUSIONS. THE BUILDING HOUSING THE BREAKER WAS KNOWN TO HAVE A LEAKING ROOF. THIS COULD HAVE ALLOWED WATER TO CONTAMINATE THE OIL IN THE TANK, RESULTING IN A DIMINISHED ARC-QUENCHING CAPABILITY OR RESULTING IN A FAULT TO GROUND. ADDITIONALLY, THE OIL CIRCUIT BREAKER HAD NOT RECEIVED SCHEDULED SERVICE OR REPAIR SINCE 1971 (13 YEARS EARLIER).

Keywords: BURN, CLOTHING, OIL CIRCUIT BREAKER, MAINTENANCE, ELECTRICAL, E PTD, ELEC UTILITY WORK, ELECTRICAL FAULT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1136126 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 1136126 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 1136126 Fatality Burn/Scald(Heat) Occupation not reported
4 1136126 Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 1136126 Hospitalized injury Bruise/Contus/Abras Occupation not reported
6 1136126 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 1136126 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.