Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14542948 - Employee killed in trench cave-in

Accident Summary Nr: 14542948 -- Report ID: 0418100 -- Event Date: 08/29/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
215698208/29/198517110Stroud Contracting

Abstract: Employee #1 was in an approximately 8 to 9 ft deep by 2 ft wide trench uncovering the sewer line to connect a house to the sewer system. The owner of the company, who was on a John Deere backhoe/loader, model 6310AD, serial #358402T, noticed the wall of the trench start to give way and yelled to his employee. Employee #1 was completely buried when the wall collapsed. He suffered multiple injuries and died shortly after being rescued. The trench was neither shored nor sloped, there was no exit ladder, and the excavated dirt was piled at the edge of the excavation.

Keywords: WORK RULES, CONSTRUCTION, TRENCH, SHORING, SLOPING, BURIED, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2156982 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.