Accident Summary Nr: 14542344 - WATER IN MOLTEN STEEL CAUSED EXPLOSION

Accident Summary Nr: 14542344 -- Report ID: 0418100 -- Event Date: 10/03/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
117609810/04/198433120Atlantic Steel Company

Abstract: EMPLOYEES #1-8 WERE INVOLVED IN A CONTINUOUS CASTING MACHINE START-UP. AFTER THEY HAD PERFORMED THE SCHEDULED MAINTENANCE, AND JUST BEFORE THE FIRST MOLTEN STEEL POUR, EMPLOYEES #1-8 WERE CALLED AWAY TO CORRECT A PROBLEM WITH ANOTHER CASTING MACHINE. AT THE TIME THEY WERE CALLED AWAY THEY WERE IN THE PROCESS OF INSTALLING NEW WATER SPRAY BARS BELOW THE CENTER MOLD OF THE MACHINE. UPON THEIR RETURN, AND AFTER THEY HAD FLUSHED THE MACHINE WITH WATER, THE POUR WAS BEGUN. THE CREW FAILED TO REALIZE THAT THE THREE UPPER SPRAY NOZZLES ON ONE SPRAY BAR HAD NOT BEEN INSTALLED. WHEN THE WATER SPRAY WAS CUT ON, THREE STREAMS OF WATER (RATHER THAN SPRAYS) STRUCK THE MOLD. SUFFICIENT FORCE WAS EXERTED TO FORCE WATER INTO THE MOLD. CONSEQUENTLY, A MOLTEN METAL EXPLOSION OCCURRED. EMPLOYEES #1-8, WHO WERE IN THE AREA, RECEIVED VARYING DEGREES OF BURNS.

Keywords: BURN, MAINTENANCE, STEEL, CASTING, EXPLOSION, MOLTEN METAL, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
5 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported
8 1176098 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.