Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 145411.015 - Employee fractures scapula after falling through floor openi

Accident Summary Nr: 145411.015 -- Report ID: 0950632 -- Event Date: 10/14/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1558244.01510/16/2021561320Swift Tradesman, Llc

Abstract: At 3:30 p.m. on October 14, 2021, an employee had been directed to replace a pre-existing 2 ft by 2 ft oriented strand board (OSB) floor-hole cover on the seventh floor of an building. The employee fell through the hole, breaking through a piece of drywall and possibly the piece of the OSB . The employee fell through uncovered floor holes in the floors below until he was able to stop his fall on the fourth floor. The employee sustained a fractured scapula and was hospitalized.

Keywords: Construction, Fall, Fall From Elevation, Fall Protection, Floor Hole, Floor Opening, Fracture, Shoulder, Temporary Floor, Unguarded, Unguarded Fl Opening
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition   7

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1558244.015 28 M Hospitalized injury Construction laborers Distance of Fall: 36 feet
Worker Height Above Ground/Floor: 5 feet
Cause: Interior carpentry
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close