Accident Summary Nr: 14538441 - EMPLOYEE EXPOSED TO ANHYDROUS AMMONIA FROM BROKEN HOSE

Accident Summary Nr: 14538441 -- Report ID: 0452110 -- Event Date: 06/02/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1862202706/04/198570110Armour Food Company

Abstract: EMPLOYEE #1 WAS PURGING NON-CONDENSABLE GAS FROM AN ANHYDROUS AMMONIA CONDENSER. HE WAS ON THE FIRST RUNG OF A LADDER, OPENING THE PURGE VALVE. A LENGTH OF BOSTON PERFECTION 1000 HIGH PRESSURE AIR AND WATER HOSE WAS BEING USED TO CONNECT THE PURGE VALVE TO THE PUMP-OUT COMPRESSOR. THE HOSE BURST NEAR EMPLOYEE #1'S FEET. HE SUSTAINED BURNS TO HIS FEET AND ONE ANKLE, AND ALSO HAD SOME INHALATION PROBLEMS. THE ACCIDENT WAS CAUSED BY THE USE OF A HOSE NOT APPROVED FOR ANHYDROUS AMMONIA. ALSO, THE HOSE WAS NOT IN GOOD CONDITION.

Keywords: BURN, WORK RULES, INHALATION, HOSE, ANHYDROUS AMMONIA, GAS LEAK, ANKLE, FOOT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18622027 Hospitalized injury Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.