Accident Summary Nr: 14538284 - PROBABLE EXPOSURE TO CARBON MONOXIDE GAS

Accident Summary Nr: 14538284 -- Report ID: 0452110 -- Event Date: 02/12/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1857980502/13/198723210Sutton Shirt Corporation

Abstract: AT ABOUT 9 AM ON FEBRUARY 12, 1987, SEVERAL EMPLOYEES BEGAN TO COMPLAIN OF HEADACHES, LIGHTHEADEDNESS AND NAUSEA. THIRTY EMPLOYEES WERE SENT TO THE LOCAL HOSPITAL AND SEVEN OF THE THIRTY ADMITTED OVERNIGHT. BLOOD TESTS TAKEN BY THE TREATING PHYSICIANS DID NOT SHOW ANY ELEVATED CARBOXYHEMOGLOBIN LEVELS. OXYGEN HAD BEEN ADMINISTERED PRIOR TO THE COLLECTION OF THE BLOOD SAMPLES. TWO WEEKS EARLIER A NATURAL GAS LEAK HAD OCCURRED AT THIS SITE. SEVERAL PERSONS BECAME ILL AND THREE WERE HOSPITALIZED FOR OBSERVATION. NO NATURAL GAS LEAK WAS FOUND BY THE GAS COMPANY REPRESENTATIVE, WHO CAME TO THE SITE THE NEXT DAY. CARBON MONOXIDE WAS FOUND TO BE ESCAPING FROM OVERHEAD GAS HEATERS, BUT WORKPLACE AIR MONITORING SHOWED ONLY SLIGHTLY ELEVATED LEVELS. THE WORKPLACE HAD BEEN WELL VENTILATED BY THE TIME THE READINGS WERE TAKEN. THE GAS HEATERS WERE OLD, AND WERE REPLACED WITH NEW UNITS ON ON FEBRUARY 14TH. THE EMPLOYEES RETURNED TO WORK ON FEBRUARY 17TH. NO FURTHER PROBLEMS WERE REPORTED.

Keywords: RESPIRATORY, VENTILATION, HEADACHE, HEATER, INHALATION, NAUSEA, DIZZINESS, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18579805 Hospitalized injury Other Textile sewing machine operators
2 18579805 Hospitalized injury Other Textile sewing machine operators
3 18579805 Hospitalized injury Other Textile sewing machine operators
4 18579805 Hospitalized injury Other Production inspectors, checkers and examiners
5 18579805 Hospitalized injury Other Textile sewing machine operators
6 18579805 Hospitalized injury Other Textile sewing machine operators
7 18579805 Hospitalized injury Other Textile sewing machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.