Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14535447 - EMPLOYEE FELL WITH BROKEN FREIGHT ELEVATOR

Accident Summary Nr: 14535447 -- Report ID: 0830300 -- Event Date: 12/07/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
64347812/10/198520770Watertown Rendering Co.

Abstract: EMPLOYEE #1 WAS PUSHING A 2-WHEELED CART, LOADED WITH BONE MEAL CAKES, FROM ONE AREA OF THE PLANT TO ANOTHER. THE EMPLOYEE WAS PUSHING THE CART ACROSS THE PLATFORM OF A FREIGHT ELEVATOR WHEN THE CHAIN HOIST BROKE, CAUSING THE ELEVATOR TO FALL TO THE BASEMENT. EMPLOYEE #1 ALSO FELL TO THE BASEMENT FLOOR AND WAS KILLED.

Keywords: FALL, ELEVATOR, BROKEN CHAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 643478 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.