Abstract: Employees #1, #2, and #4, all laborers, and Employee #3, an operating engineer, were working on a construction project when the coffee truck arrived at approximately 9:30 a.m. The approximately 25 site workers gathered in the vicinity of the coffee truck for a break. They congregated around the base of an approximately 60 ft long by 23 ft high concrete block wall. The first 10 vertical ft of the wall was composed of 8 in. by 8 in. concrete blocks, and the remainder was built of 12 in. by 8 in. by 16 in. blocks. No masonry work had been done on the block wall for approximately one week. The wall started to fall in, and there was a loud noise when the it struck and pushed over a metal tubular welded-frame scaffold that was standing adjacent to the wall. All the workers scrambled to safety except for Employees #1 through #3, who were trapped under the debris and killed. Employee #4 ran and fell to the ground just beyond the downed block wall, injuring his left knee and calf.

Keywords: COLLAPSE, FALL, STRUCK BY, KNEE, WALL, UNSECURED, LEG, BLOCKS, PINNED, CONSTRUCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2066454 Fatality Other Occupation not reported
2 2066520 Occupation Not Listed
3 913640 Non Hospitalized injury Strain/Sprain Occupation not reported
4 2066454 Fatality Other Occupation not reported
5 2066454 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.