Accident Summary Nr: 14529895 - EMPLOYEE DIED FROM OXYGEN DEPRIVATION IN CONFINED SPACE

Accident Summary Nr: 14529895 -- Report ID: 0111700 -- Event Date: 03/23/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10104634003/24/198734430Process Engineering

Abstract: AT APPROXIMATELY 6 PM ON MARCH 23, 1987, EMPLOYEE #1 ENTERED AN ULTRA PURE STAINLESS STEEL TANK, STILL UNDER CONSTRUCTION, INTENDING TO USE A HAND-HELD NITROGEN-SUPPLIED AIR HOSE TO DRY THE INTERIOR SUFACES OF THE TANK. ANOTHER EMPLOYEE, NEWLY HIRED, WATCHED EMPLOYEE #1 FROM OUTSIDE THE TANK. THE TANK WAS APPROXIMATELY 12.2 FEET LONG AND 5.5 FEET IN DIAMETER, WITH A 1.5 FOOT CYLINDRICAL ENTRANCE/EXIT. AFTER SEVERAL MINUTES, EMPLOYEE #1 LAY DOWN INSIDE THE TANK WITH THE NITROGEN STILL COMING OUT THE HOSE. A THIRD EMPLOYEE HAPPENED TO PASS BY AND ASKED THE SECOND EMPLOYEE WHERE EMPLOYEE #1 WAS AND WHAT HE WAS DOING. THE THIRD EMPLOYEE THEN SAW EMPLOYEE #1 LYING DOWN IN THE TANK. HE TOLD THE SECOND EMPLOYEE "WE HAVE TO GET HIM OUT". AS THE THIRD EMPLOYEE TURNED AWAY FOR A FEW SECONDS THE SECOND EMPLOYEE (EMPLOYEE #2) ENTERED THE TANK. HE COLLAPSED IN ONLY A FEW MOMENTS. THE THIRD EMPLOYEE AND A HELPER WERE ABLE TO PULL EMPLOYEE #2 OUT OF THE TANK BY PULLING HIM BY HIS HAIR FROM OUTSIDE THE TANK. THE FOURTH EMPLOYEE DONNED A SCBA AND RESCUED EMPLOYEE #1 FROM THE TANK. EMPLOYEE #1 DIED. EMPLOYEE #2 RECOVERED COMPLETELY. THERE WERE NO RESPIRATORS AT THE TANK PRIOR TO ENTRY. EMPLOYEES #1 AND #2 WERE UNTRAINED IN THE HAZARDS OF WORKING WITH NITROGEN GAS (OXYGEN DISPLACEMENT). EMPLOYEE #1 HAD DONE SIMILAR WORK ON ONE PREVIOUS OCCASION. AT THAT TIME HE HAD WORN APPROPRIATE RESPIRATORY GEAR.

Keywords: OXYGEN DEFICIENCY, UNCONSCIOUSNESS, CONFINED SPACE, WORK RULES, TANK, UNTRAINED, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101046340 Fatality Asphyxia Occupation not reported
2 101046340 Non Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close