Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14529788 - Employee killed when crushed by robot

Accident Summary Nr: 14529788 -- Report ID: 0111700 -- Event Date: 03/13/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
1790358403/13/199333650Wyman-Gordon Inv Castings Inc Dba Pcc Structurals

Abstract: Employee #1, the operator of a robot, went to investigate and/or fix a malfunction in the robot without locking it out. When Employee #1 tried to fix the system, he activated the robot and the robot's arm crushed him against a part being transported on a conveyor. Employee #1 was killed.

Keywords: CHEST, REPAIR, ROBOT, WORK RULES, LOCKOUT, CAUGHT BETWEEN, CRUSHED, CONVEYOR, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 17903584 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.