Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14528681 - BURNS FROM DUST COLLECTION SYSTEM FIRE AND EXPLOSION

Accident Summary Nr: 14528681 -- Report ID: 0111700 -- Event Date: 08/31/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
93904108/31/198436610Northern Telecom Inc Nss Division

Abstract: AN EMPLOYEE WAS BURNED WHILE STANDING AT THE FEED END OF A TIME SAVER SANDING MACHINE (MODEL TOP 18, HAVING A 18" X 85" NORTON 180 GRIT METALITE SANDING BELT). APPARENTLY A FIRE IN THE DUST COLLECTOR CONNECTED TO THE TIME SAVER MACHINE BLEW BACK THROUGH THE DUCTWORK OF THE MACHINE EXHAUST HOODS AND ONTO THE EMPLOYEE'S BODY. THE TIME SAVER SANDING MACHINE COLLECTS STEEL AND ALUMINUM DUST FROM THE SURFACE SANDING OF STEEL OR ALUMINUM PARTS PROCESSED THROUGH THE MACHINE. AT THE TIME OF THIS ACCIDENT THE TIME SAVER MACHINE OPERATOR WAS FEEDING STEEL PARTS INTO THE SANDER. THIS PROCESS NORMALLY GENERATES VISIBLE SPARKS AT THE POINT OF SANDING. IN THIS INSTANCE THE SPARKS BECAME PLUGGED AT THE LOCAL EXHAUST HOOD, NEAR THE SANDING BELT ON THE MACHINE, PRODUCING A GLOWING MOSS OF METAL. THE MACHINE OPERATOR CALLED EMPLOYEE #1. EMPLOYEE #1 CAME INTO THE ROOM TO WATCH THE SANDING MACHINE OPERATOR TRY TO DISLODGE THE GLOWING MOSS WITH A ROD WHILE STANDING ON THE SIDE OF THE MACHINE. EMPLOYEE #1 THEN SAW THE FLEXIBLE RUBBER DUCTWORK BEHIND THE SANDING MACHINE OPERATOR BEGIN TO SMOKE. EMPLOYEE #1, NOW STANDING AT THE FEED END OF THE SANDING MACHINE, ATTEMPTED TO TURN OFF THE ELECTRIC CURRENT TO THE DUST COLLECTION SYSTEM. AT THIS TIME, THE FLASH FIRE OCCURRED AND BURNED THE FRONT OF HIS BODY FROM THE WAIST UP. THE ALUMINUM DUST APPARENTLY CAUGHT FIRE FROM THE STEEL SPARKS FEEDING INTO A MODEL 20.5 FB-55 TORIT DUST COLLECTION SYSTEM (DRY TYPE WITH 4 FABRIC FILTER BAGS). THIS SYSTEM WAS LOCATED OUTDOORS. THE ENTIRE OPERATION WAS NOT IN COMPLIANCE WITH NFPA STD #65 ON ALUMINUM PROCESSING, INVOLVING THE GRINDING, SANDING AND POLISHING OF ALUMINUM MATERIALS.

Keywords: BURN, SANDING MACHINE, DUST, ALUMINUM DUST, ALUMINUM PROCESSING, FIRE, DUST COLLECTOR, SPARK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 939041 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.