Accident Summary Nr: 14526354 - Employee crushed and killed by boom during disassembly

Accident Summary Nr: 14526354 -- Report ID: 0418800 -- Event Date: 09/06/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
120480909/09/198516290Berkel & Company Contractors Inc.

Abstract: A crane crew was disassembling the boom of an FMC Link Belt crawler crane, LS98A, before transporting the crane to another job site. The boom consisted of three 20 foot sections: a base, one insert, and a point. Employee #1 signaled the crane operator to raise the boom. He then removed the lower pin cotter keys and, with a hammer, knocked out both bottom pins connecting the point section and the insert. He was under the insert while removing the pins, and the boom fell and crushed him to death. The boom hoist pendants had not been reconnected to a point behind the pins to be removed, nor was the boom supported by blocking. This fatality could have been prevented by close supervision to see that safe boom disassembly procedures were followed and that employees never stood under a boom while removing the pins.

Keywords: DISMANTLING, BLOCKS, CRANE BOOM, WORK RULES, CRAWLER CRANE, CONSTRUCTION, CRUSHED, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1204809 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close