Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14525661 - ELECTRIC SHOCK - FAULTY UTILIZATION EQUIPMENT

Accident Summary Nr: 14525661 -- Report ID: 0418800 -- Event Date: 04/19/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
122805504/24/198417110Al Hill Plumbing Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
122811304/24/198415420All Type Projects Inc

Abstract: AN EMPLOYEE WAS OPERATING A SKIL ROTO HAMMER (MODEL NO. 736, SERIAL NO. 707886), WHICH WAS RATED 120 VOLTS, 11 AMPERES. THE HAMMER WAS CONNECTED, THROUGH A 100-FOOT CORD SET, TO A PERMANENT DUPLEX RECEPTACLE OUTLET INSTALLED ON A BUILDING. THE CORD SET HAD THE GROUNDING PRONG MISSING FROM ITS ATTACHMENT PLUG. THE HAMMER WAS NOT DOUBLE INSULATED. THE EMPLOYEE HAD COMPLAINED TO ANOTHER EMPLOYEE ABOUT GETTING SHOCKED. THE SECOND EMPLOYEE MADE MINOR REPAIRS TO THE TOOL'S FRAYED POWER CORD AND THEN USED THE HAMMER FOR ABOUT 1/2 HOUR WHILE HE WAS STANDING ON DAMP SOIL. HE WAS CUTTING A HOLE IN THE BOTTOM AND SIDE OF A CATCH BASIN FROM THE OUTSIDE. THE SECOND EMPLOYEE INSTRUCTED OTHER EMPLOYEE TO FINISH THE HOLE FROM INSIDE THE CATCH BASIN, WHERE THE EARTH WAS ALSO DAMP. AFTER ABOUT 20 MINUTES OF WORK WITH THE ELECTRIC HAMMER, THE FIRST EMPLOYEE WAS ELECTROCUTED.

Keywords: ELECTRICAL, ATTACHMENT PLUG, E C, EQUIPMENT GROUNDING, ELEC PORT TOOL--MISC, CORD SET, ELECTROCUTED, ELECTRIC CORD, ROTARY HAMMER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1228055 Fatality Electric Shock Occupation not reported
2 1228113 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close