Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14521454 - Six employees injured in fire and explosion

Accident Summary Nr: 14521454 -- Report ID: 0524500 -- Event Date: 02/17/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10015133102/17/198730890Teepak, Inc.

Abstract: On February 17, 1987, a fire and explosion occurred at a process machine where viscose casings are manufactured. A buildup of carbon disulfide occurred at tank #3 of process machine #9 and the vapors were probably ignited by a heat exchanger at that tank. The fire was sucked into the ventilation system and spread to other parts of the process area. Employees #1 through #6 were all in the process area. Employee #1 was at the wet end of machines #1 and #2, and suffered from smoke inhalation. Employee #2 was at the extrusion end between machines #9 and #10, and sustained second-degree burns on his hands and arms. Employee #3 was at tank #7 between machines #9 and #10, and suffered burns on his back. Employee #4 was at the extrusion end of machine #5, and was injured by foreign objects in his eyes. Employee #5 was at the dry end between machines #8 and #9, and complained of throat irritation. Employee #6 was by the old "B" tanks of machine #9, and suffered from smoke inhalation. Employees #1, #2, and #6 were hospitalized. A semi-continuous monitoring system was being installed to detect carbon disulfide, hydrogen sulfide, and ammonia, but it was not yet operational. There were gaps in the insulation on the heat exchanger and the surface temperature of the exchanger was just slightly below 140 degrees Fahrenheit.

Keywords: BURN, FLAMMABLE VAPORS, FIRE, INHALATION, EXPLOSION, HEAT EXCHANGER, CHEMICAL VAPOR, CARBON DISULFIDE, SMOKE INHALATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100151331 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 100151331 Hospitalized injury Asphyxia Occupation not reported
3 100151331 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 100151331 Hospitalized injury Asphyxia Occupation not reported
5 100151331 Non Hospitalized injury Other Occupation not reported
6 100151331 Non Hospitalized injury Foreign Body Ineye Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.