Accident Summary Nr: 14521280 - Employee dies while suspended by safety belt

Accident Summary Nr: 14521280 -- Report ID: 0524500 -- Event Date: 05/18/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10327863605/19/199273490Clear Day, Inc.

Abstract: On May 18, 1992, Employee #1 was washing windows on a six story building. He was using a wood seat assembly attached to a friction descent device and was wearing a safety belt and lanyard attached to an independent lifeline. When he went over the parapet wall, he did not hook up his seat assembly. He fell 6 ft and was suspended by his safety belt 50 ft above ground level. A delay in rescue efforts resulted in his death of asphyxia due to the safety belt compressing his diaphragm and lungs.

Keywords: WINDOW WASHER, LUNG, ASPHYXIATED, ROOF, EMERGENCY RESPONSE, UNSECURED, WORK RULES, SAFETY BELT, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103278636 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.