Accident Summary Nr: 14520969 - Employee killed when crushed in overturning crane

Accident Summary Nr: 14520969 -- Report ID: 0524530 -- Event Date: 08/30/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10258283009/02/198817990Mcclelland Services, Inc.

Abstract: Employee #1 was operating a truck-mounted hydraulic crane to remove a sump pump from an excavation. The crane was parked with the rear of the truck against the side of the excavation. The crane's rear outriggers were extended; the front outriggers were not. The pump was hoisted with the boom over the rear of the truck. The boom was then traversed over the side of the truck. While the crane load was being spotted, the crane and truck overturned, pinning Employee #1 between the passenger side control station and a generator located along the passenger side of the truck-mounted crane. Employee #1 was killed.

Keywords: COUNTERBALANCE, TRUCK CRANE, CONSTRUCTION, CAUGHT BETWEEN, CRUSHED, CRANE, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102582830 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close