Accident Summary Nr: 14519987 - Nine employees burned, three killed, in barge explosion

Accident Summary Nr: 14519987 -- Report ID: 0625700 -- Event Date: 03/19/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10163806203/20/198737310Production Management Industries
Inspection NrDate OpenedSICNAICSEstablishment Name
10163807003/24/198717710Holes Of Louisiana, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10163806203/20/198737310Production Management Industries

Abstract: At approximately 5:15 p.m. on March 18, 1987, a crew of six employees was repairing the end of a concrete barge on Lake Maurepas. They ignited flammable paraffin wax fumes that were in the compartments of the barge, causing an explosion and fire. Employees #1 through #3 were killed, and Employees #4 through #9 sustained burns and other injuries. Employees #4 through #6 were hospitalized.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, BARGE, REPAIR, VAPOR, FIRE, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101638062 Fatality Fracture Occupation not reported
2 101638062 Fatality Fracture Occupation not reported
3 101638062 Fatality Fracture Occupation not reported
4 101638062 Hospitalized injury Fracture Occupation not reported
5 101638070 Hospitalized injury Fracture Occupation not reported
6 101638062 Hospitalized injury Burn(Chemical) Occupation not reported
7 101638062 Non Hospitalized injury Strain/Sprain Occupation not reported
8 101638062 Non Hospitalized injury Strain/Sprain Occupation not reported
9 101638062 Non Hospitalized injury Strain/Sprain Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.