Accident Summary Nr: 14519706 - TRAVELLING BLOCK FELL TO RIG DECK, STRIKING TWO EMPLOYEES

Accident Summary Nr: 14519706 -- Report ID: 0625700 -- Event Date: 06/22/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10108327707/09/198613810Henley Drilling Company

Abstract: AT APPROXIMATELY 8:50 PM ON JUNE 22, 1986, EMPLOYEES #1 AND #2 WERE WORKING ON THE FLOOR OF DRILLING RIG #7. THE TRAVELLING BLOCK WAS RUN INTO THE CROWN BLOCK, CAUSING THE WIRE ROPES TO BREAK. THE TRAVELLING BLOCK FELL TO THE RIG FLOOR AND REBOUNDED INTO EMPLOYEE #1, STRIKING HIM ON THE LEFT ELBOW AND SHOULDER. HIS LEFT ARM WAS AMPUTATED ON SITE BY A DOCTOR WHO WAS CALLED TO THE SCENE. EMPLOYEE #2 SUSTAINED SEVERAL ABRASIONS OF HIS LEFT LEG. EMPLOYEE #1, WHO WAS AIRLIFTED TO THE HOSPITAL, DIED ON JULY 3, 1986.

Keywords: SHOULDER, TRAVELLING BLOCK, OIL WELL DRILLING, CROWN BLOCK, STRUCK BY, TWO-BLOCKING, ARM, FALLING OBJECT, OIL RIG, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101083277 Fatality Amputation Occupation not reported
2 101083277 Hospitalized injury Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close