Accident Summary Nr: 14519433 - Two employees killed, five hurt in fall while shoring fails

Accident Summary Nr: 14519433 -- Report ID: 0625700 -- Event Date: 01/21/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10182054601/21/198617990Chemipulp Process, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10181867201/21/198617110Southern Erectors Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
10181868001/23/198626110Georgia Pacific Corp
Inspection NrDate OpenedSICNAICSEstablishment Name
10182055301/21/198615410Brown & Root Usa
Inspection NrDate OpenedSICNAICSEstablishment Name
10182054601/21/198617990Chemipulp Process, Inc.

Abstract: Employees #1 through #7 and a coworker were placing concrete for the roof of a pulp tank. The form was supported by 40 ft of shoring, with joist ledgers and put locks. As the concrete was being poured, the form and shoring system collapsed. Employees #1 through #7 fell with the form, and Employees #1 through #6 became entangled with the shoring system and concrete. Employees #1 and #2 were killed, and Employees #3 through #6 were hospitalized. The shoring system had not been properly installed as outlined in the drawings. The use of too few ledgers and ledgers of an incorrect size caused the shoring to fail.

Keywords: SHORING, ENTANGLED, COLLAPSE, FALL, CONCRETE FORM WORK, WORK RULES, EQUIPMENT FAILURE, ROOF, CONSTRUCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101820546 Hospitalized injury Other Occupation not reported
2 101820546 Fatality Amputation Occupation not reported
3 101820546 Hospitalized injury Fracture Occupation not reported
4 101820546 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
5 101818672 Occupation Not Listed
6 101818680 Occupation Not Listed
7 101820553 Occupation Not Listed
8 101820546 Hospitalized injury Fracture Occupation not reported
9 101820546 Fatality Amputation Occupation not reported
10 101820546 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.