Accident Summary Nr: 14517882 - One employee killed, three injured in scaffold collapse

Accident Summary Nr: 14517882 -- Report ID: 0419700 -- Event Date: 02/10/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10034093402/11/198637310Jacksonville Shipyards Inc

Abstract: Workers in a Navy yard were removing a rudder stock from a Navy vessel in dry dock when the two lifting eyebolts (supplied by the Navy) fractured. The 28,500 lb rudder stock fell, striking the scaffold from which Employees #1 and #2 were working. The scaffold collapsed, killing Employee #1 and injuring Employee #2. Employees #3 and #4 also sustained injuries and Employee #3 was hospitalized.

Keywords: SHIPYARD, COLLAPSE, EQUIPMENT FAILURE, BOLT, STRUCK BY, FALLING OBJECT, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100340934 Fatality Other Occupation not reported
2 100340934 Hospitalized injury Other Occupation not reported
3 100340934 Hospitalized injury Other Occupation not reported
4 100340934 Non Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.