Accident Summary Nr: 14517130 - Three employees burned by hot resin; one later dies

Accident Summary Nr: 14517130 -- Report ID: 0419700 -- Event Date: 03/11/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
168788803/13/198428210St Johns Chemical Corp

Abstract: Employees #1 and #2 were preparing to transfer hot resin. They had blown out the transfer line when a patch welded to the lower side of the tank gave way and hot resin spilled on them. Employees #1 and #2 sustained serious burns, and Employee #1 later died. Employee #3, age 19, went to help his coworkers and slipped in the hot resin. He was hospitalized with burns.

Keywords: BURN, SLIP, BROKEN WELD, EQUIPMENT FAILURE, SLIPPERY SURFACE, TANK, HIGH TEMPERATURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1687888 Fatality Burn(Chemical) Occupation not reported
2 1687888 Hospitalized injury Burn(Chemical) Occupation not reported
3 1687888 Hospitalized injury Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.