Accident Summary Nr: 14516926 - Employee killed when struck by falling crane load

Accident Summary Nr: 14516926 -- Report ID: 0420600 -- Event Date: 09/29/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10126878709/30/198716230National Utilities Construction Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10126877909/30/198716230D.E. Britten Incorporated

Abstract: A sheave on a hydraulic crane slipped from its retaining bracket, causing a partially loaded clamshell bucket to drop. The bucket struck Employee #1, crushing and killing him. Subsequent investigation revealed a shut load-bearing plate on the sheave. This likely resulted in the sheave becoming overloaded and the retaining pin being pulled out of its mounting bracket. When the sheave flew out from its mounting, the load line slipped and the bucket fell.

Keywords: SUSPENDED LOAD, CONSTRUCTION, EQUIPMENT FAILURE, CRUSHED, STRUCK BY, FALLING OBJECT, HYDRAULIC CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101268787 Occupation Not Listed
2 101268779 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.